Sign In | Join Free | My fnxradio.com
China Chongqing Bio Newvision Medical Equipment Ltd. logo
Chongqing Bio Newvision Medical Equipment Ltd.
Build Ophthalmic Equipment Flag Exploit Dignosis New Era
Verified Supplier

5 Years

Home > Optical Coherence Tomography Machine >

2.5mm Optical Coherence Tomography Machine For Fundus Disease

Chongqing Bio Newvision Medical Equipment Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

2.5mm Optical Coherence Tomography Machine For Fundus Disease

  • 1
  • 2

Brand Name : SYSEYE

Model Number : RetiView 500

Certification : TUV

Place of Origin : China

MOQ : 1

Price : $18,500.00-$21,900.00

Payment Terms : T/T

Supply Ability : 100

Delivery Time : 5 working days

Packaging Details : 497 mm × 395 mm × 490 mm (L × W × H) 34 kg (75 lbs)

product name : Easy Installation Optical Coherence Tomography Machine

Dimensions Weight : 34 kg (75 lbs)

Axial resolution : ≤6 µm (in tissue)

Transverse resolution : ≤20 µm (in tissue)

Scan depth : ≥2.5 mm (in air)

Focus adjustment : -15D to +15D

Pupil diameter : ≥3 mm

feature : Easy Installation No Complex Connection Or Setup

Contact Now

Easy Installation No Complex Connection Or Setup Optical Coherence Tomography Machine

Optical Coherence Tomography Machine is an auxiliary diagnostic method in ophthalmology, which is widely used and can provide good help to ophthalmologists. It is mainly used in two aspects: one is suitable for corneal disease; There is also a suitable for fundus disease, it can show the structure of the cornea at all levels and subtle changes, a great help to the doctor of corneal disease. It is more used for the diagnosis and differential diagnosis of fundus diseases, such as common macular diseases, macular degeneration, macular hole, anterior macular membrane, vitreous macular traction syndrome and so on. The diagnosis of these diseases all requires the examination results of OCT. As well as optic disc atrophy, optic disc small concave, optic disc disease auxiliary examination, also need to rely on the results of OCT examination for diagnosis and differential diagnosis.

Compact Design

Features:

1. Compact Design: Everything is inside this compact body. No external computer is needed. Plug in the power cable, then you are ready to go.
2. PC Inside: Data acquisition and processing are accomplished by the internal computer. The data can be transported via ethernet or external harddrive. Peripheral devices, such as keyboard or printer, can be connected to the computer ports.
3. Easy Installation:No complex connection or setup. Compact body can fit in even small space.

Specifications of Optical Coherence Tomography Machine

Methodology Spectral domain OCT
Axial resolution ≤6 µm (in tissue)
Transverse resolution ≤20 µm (in tissue)
Scan depth ≥2.5 mm (in air)
Scan range ≥6 mm
Scan speed ≥24,000 A-scans/sec, up to 36,000 A-scans/sec
Scan modes 3D, Raster, Circle
Fundus image OCT en face
Focus adjustment -15D to +15D
Pupil diameter ≥3 mm
OCT light source 840 nm SLD
Optical power 750 µW (at cornea)
Operation 13.3” touch screen, optional external mouse or keyboard 100-240 V, 50/60 Hz
Power supply 497 mm × 395 mm × 490 mm (L × W × H)
Dimensions Weight 34 kg (75 lbs)

Optical Coherence Tomography Machine has never been so affordable. More people can benefit from the advanced technology now.

Step 1
Choose left or right eye. Push the direction buttons to move the target eye to the center of the field of view, then start data acquisition.
Step 2
Enter the data acquisition interface. The device is able to search for the OCT signal and optimize it automatically.
Step 3

Browse and analyze the acquired images.

2.5mm Optical Coherence Tomography Machine For Fundus Disease

2.5mm Optical Coherence Tomography Machine For Fundus Disease

2.5mm Optical Coherence Tomography Machine For Fundus Disease

2.5mm Optical Coherence Tomography Machine For Fundus Disease

2.5mm Optical Coherence Tomography Machine For Fundus Disease

Company Introduction

2.5mm Optical Coherence Tomography Machine For Fundus Disease

Focusing on the two major public health problems of adolescent myopia and elderly ophthalmology, our company researches new diagnostic and treatment equipment for ophthalmology, develops low-cost applicable technology products, realizes industrialization, reduces the cost of social medical and health system, and serves the strategic needs of national health.The company always adhere to the "high-tech,new vision" for the enterprise development concept.We have a strong technical force, has been awarded 11 patents, and obtained 13,485 quality system certification.Bio has established an efficient marketing team and a perfect after-sales service system to provide medical equipment with the highest cost performance and meticulous service.

2.5mm Optical Coherence Tomography Machine For Fundus Disease


Product Tags:

2.5mm Optical Coherence Tomography Machine

      

3D Optical Coherence Tomography Machine

      

Fundus Disease oct scan machine

      
Wholesale 2.5mm Optical Coherence Tomography Machine For Fundus Disease from china suppliers

2.5mm Optical Coherence Tomography Machine For Fundus Disease Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Chongqing Bio Newvision Medical Equipment Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)